Home   |     Products   |    Careers    |    Clients    |    Contact us       

Telemetry

35 Channel Signal Conditioning and

Processing Unit : VTSCP

 

Description:

 

The 35 Channel Signal Conditioning and Processing Unit does the required signal conditioning for different types of sensor signals (Pressure, Vibration and RTD) to + 10V and processes them using programmable signal conditioners , ADC and FPGA. The processed digital data is also made available via RS422 in a defined format. 

The unit consists of two signal conditioning cards and a power supply card.

 

 

 

FEATURES

 

Sensor characterstics

 Type

 No. of Channels

 Range

 Band width

 pressure

 5

 0-45 mV or
 0-20 mV

 150Hz.

 RTD             

 9

 100 – 375

 50 Hz.

 Vibration

 21

 ±5g

 2000 Hz.

 Other Features

 No. of Channels

 35

 Analog Output

 ±10V

 Digital Output

 RS422

 Power supply          

 28V ± 4V DC

 Functional Specific

 Unit as per EMI/EMC standards

 Transmission facility through RS422/RS485

 Facility to accommodate different kind of sensors signaling  conditioning circuits  on the same board

 Provision of dynamic configuration on RS422 for sampling rates  and number of  channels.

 Dimensions of the unit

 6U