Telemetry
35 Channel Signal Conditioning and
Processing Unit : VTSCP
Description:
The 35 Channel Signal Conditioning and Processing Unit does the required signal conditioning for different types of sensor signals (Pressure, Vibration and RTD) to + 10V and processes them using programmable signal conditioners , ADC and FPGA. The processed digital data is also made available via RS422 in a defined format.
The unit consists of two signal conditioning cards and a power supply card.
FEATURES |
|||
|
|||
Sensor characterstics |
|||
Type |
No. of Channels |
Range |
Band width |
pressure |
5 |
0-45 mV or |
150Hz. |
RTD |
9 |
100 – 375 |
50 Hz. |
Vibration |
21 |
±5g |
2000 Hz. |
Other Features |
|||
No. of Channels |
35 |
||
Analog Output |
±10V |
||
Digital Output |
RS422 |
||
Power supply |
28V ± 4V DC |
||
Functional Specific |
Unit as per EMI/EMC standards |
||
Transmission facility through RS422/RS485 |
|||
Facility to accommodate different kind of sensors signaling conditioning circuits on the same board |
|||
Provision of dynamic configuration on RS422 for sampling rates and number of channels. |
|||
Dimensions of the unit |
6U |
||